Try our Urine Protein Concentration Calculator 

Vivaproducts - Protein Purification and Separation Technologies

Centrifugal ultrafiltration

Protein concentration and buffer exchange, faster and with higher recovery

Vivaspin centrifugal concentrators deliver reproducible results across a broad range of sample volumes and applications. With the widest selection of membrane options and MWCO formats, Vivaspin fits into your workflow with minimal adjustment and maximum performance.

400x
Concentration factor
2k to 100k
MWCO range (Da)
0.5 to 100 mL
Sample volume range
Typical workflow
Load sample
0.5 mL to 100 mL starting volume
Centrifuge
Results in minutes, not hours
Recover concentrated sample
High recovery with low dead volume design
Trusted for
mAb concentration
Buffer exchange and diafiltration
Viral vector prep (AAV, LVV)
Oligonucleotide desalting
Recombinant protein purification
Antibody concentration for diagnostics

Why Vivaspin

Built for high-recovery protein workflows

Every design decision in Vivaspin is optimised to minimise sample loss, increase reproducibility, and reduce processing time.

High protein recovery

Low dead volume design across the Vivaspin range minimises sample loss. The Vivaspin 2 features a reverse spin step for up to 98% recovery, making it well suited for precious or low-abundance samples.

Up to 0%
recovery (Vivaspin 2)

Low-binding membranes and broad MWCO range

PES and Hydrosart membranes minimise non-specific protein adsorption, while CTA provides a cellulose option for sensitive samples. Available in MWCO formats from 2,000 to 100,000 Da across all volume formats.

Faster sample prep

Perform buffer exchange and concentration in a single centrifugation step. Reduce hands-on time significantly compared to dialysis, with no overnight wait de-risk protein loss with no additional desalting steps.

Scalable across volumes

Consistent performance from 0.5 mL microvolume samples up to 100 mL pilot-scale workflows. Use the same membrane chemistry and MWCO across formats as your workflow scales.

Expert technical support

Application specialists are available to help validate your MWCO selection, confirm membrane compatibility, and optimise your protocol for your specific sample type and workflow requirements.

Performance overview

Key performance figures

Up to 98%
Protein recovery (Vivaspin 2 reverse spin)
Up to 400x
Maximum concentration factor
0.5 to 100 mL
Sample volume range
2k to 100k Da
Available MWCO range

Products

Choose by volume and workflow

All models share the same membrane portfolio (PES, Hydrosart, CTA) and MWCO options from 2k to 100k Da.

Vivaspin 500

Microvolume concentration for small and precious samples with minimal loss.

Sample volume 100 to 500 mL
Concentrate to ~10 µL
Ideal for Low-volume protein prep, oligos
MWCO
3k 5k 10k 30k 100k 300k 1000k
Membrane
PES RC CTA

Vivaspin 20

High-throughput concentration with up to 250x concentration factor, suited for routine biologics and viral vector workflows.

Sample volume 2 to 6 mL
Concentrate to 30 µL
Ideal for Biologics, viral vector concentration
MWCO
3k 5k 10k 30k 50k 100k 0.2µm
Membrane
RC CTA PES

Vivaspin Turbo 15 / 20 / 100

Large-volume formats for process development and pilot-scale workflows, with high throughput and reliable performance across batches.

Sample volume Up to 100 mL
Concentrate to ~1 mL
Ideal for Process development, AAV/LVV, scale-up
MWCO
2k 3k 5k 10k 30k 100k 300k 1000k 0.2µm
Membrane
RC CTA PES

Membranes

Select the right membrane for your sample

Three membrane chemistries with distinct binding and compatibility profiles. Choose the one that matches your protein type and workflow requirements.

PES (Polyethersulfone)

General purpose

High flow rate and low non-specific binding. The standard choice for most protein concentration and buffer exchange applications. Compatible with most aqueous buffers.

Hydrosart (Modified Cellulose/RC)

Low-binding

Ultra-low-binding membrane for sensitive, sticky, or low-abundance proteins. Well suited for mAbs, fusion proteins, and applications where maximum recovery is the primary requirement.

CTA (Cellulose Triacetate)

Specialty

Excellent biocompatibility for enzyme and oligonucleotide applications. A good fit for samples sensitive to synthetic membrane surfaces, with natural cellulose chemistry and low protein binding.

Applications

Validated for leading protein workflows

Validated across the modern protein lab

From microvolume oligo desalting to pilot-scale viral vector concentration, Vivaspin formats are deployed in workflows across antibody discovery, gene therapy, and process development.

6+ workflows
covered by a single product family

Antibody and mAb workflows

mAb concentration
Antibody buffer exchange
Formulation and diafiltration

Recombinant proteins and enzymes

Post-purification concentration
Protein desalting
Enzyme buffer exchange

Gene therapy and viral vectors

AAV concentration
LVV (lentiviral vector) prep
Nanoparticle sample recovery

Nucleic acids

Oligonucleotide desalting
Oligo concentration
Post-synthesis clean-up

Buffer exchange and diafiltration

Replace PD-10 and dialysis
Centrifugal UF/DF
Rapid formulation buffer swap

Biologics and process development

Post-lysis clarification
Pilot-scale concentration
Biosimilar and biologics prep

Free sample request

Try Vivaspin in your workflow at no cost

Tell us about your application and we will send the right Vivaspin format and MWCO directly to your lab. A specialist will follow up to help you optimise your protocol.

Receive the right MWCO and format for your protein or sample type
Access to validated protocols and application notes
Follow-up support from a Vivaproducts application specialist
No obligation, just hands-on data from your own samples
Thanks! Your request has been received. A specialist will be in touch shortly.

By submitting, you agree to be contacted by a Vivaproducts specialist. No spam. See our privacy policy.

Our Products